May 2009 AfiFree Terminal 155i Installation Manual 39
Connecting to a Plug-in Connection Box
1. Plug the AfiFree Body pigtail cable into the AfiFree body plug-in connection
cable (for available lengths and part numbers see Table 3, page 21).
2. Route the AfiFree body plug-in connection cable to the PICB.
3. Plug the AfiFree body plug-in connection cable into socket 9 of the PICB.
Mounting and Wiring Terminal 155i
Mounting and wiring Terminal 155i has the following parts:
Terminal 155i Bracket Mounting (below)
Mounting the Terminal 155i (page 40)
Wiring Terminal 155i (page 41)
Terminal 155i Bracket Mounting
The options for mounting the Terminal 155i bracket are described in these sections.
Mounting the Terminal 155i Bracket Welded to a Pipe
1. Determine the best location for Terminal 155i bracket in accordance with
Terminal 155i Positioning (page 28).
2. Position the mounting bracket, and secure it in place with a clamp.
3. Weld the bracket in place at the points illustrated in Figure 18.
Figure 18: Welding the Terminal 155i bracket to a pipe