44 Chapter 3 Mounting and Wiring P/N 9040322
Connecting
AfiMilk
Solenoids to a Plug-in Connection Box
1. Plug the Cluster Removal Solenoid cable into socket 3 of the PICB.
2. Plug the Vacuum Shutoff, Sweep Solenoid cable into socket 4 of the PICB.
Wiring Non-
AfiMilk
Solenoids to a Plug-in Connection Box
Wire a non-AfiMilk Cluster Removal Solenoid or non-AfiMilk Vacuum Shut-off
Sweep Solenoid, as follows:
1. Cut off the solenoid connection cable’s yellow wire.
2. Wire the blue and brown wires to the solenoid (Table 8).
3. Plug the connector of the solenoid connection cable into the PICB as follows:
a. Plug the cable from the Cluster Removal Solenoid into socket 3.
b. Plug the cable from the Vacuum Shut-off Sweep Solenoid into socket 4.
Table 8: Wiring a Non-AfiMilk Solenoid
Color of Wire on
Connection Cable
(P/N 4097327)
DC Cluster Removal
Solenoid
Vacuum Shut-Off, Sweep
Solenoid
Wiring the Pulsator
Take appropriate precautions to prevent injury from electric shock.
Connect the pulsator as follows:
Installations using AfiFree Connection Boxes—see Wiring the Pulsator to an
AfiFree Connection Box (below).
Installations using PICBs—see Connecting the Pulsator to a Plug-in Connection
Box (below).
Wiring the Pulsator to an
AfiFree
Connection Box
Wire the Pulsator to the connection box according to Figure 17 (page 38).