Chapter 5 Troubleshooting
This chapter contains the following:
Guidance on searching for the source of an electrical problem (below)
Troubleshooting Guide(below)
For the meaning of lit or flashing LEDs on a Terminal 155i, see Table 25: Operating
Modes and their Indicators (page 97) and Table 28: Alarm and Malfunction Indicators
(page 117).
Searching for an Electrical Problem
To search for electrical problems, proceed as follows until the problem is resolved:
1. Check all connections in the connection box:
a. Verify that wire colors match the wiring diagram in the lid of the Connection
Box.
b. Check for poor contacts.
2. Replace the Terminal 155i.
3. Replace the AfiFree Body.
Table 21: Troubleshooting Guide
Display panel is not
illuminated
Faulty connection of
power supply (24 V) cable
to the control unit
Check the power connection
Insufficient power supply
Verify that the last AfiFree155i
milk meter on each side is
being supplied with 24V± 3.6V
Terminal 155i does not
display identification of
animals
Identification or antenna
problem
Consult manual for
identification system:
AfiPass64 Installation
Manual (P/N 9040610)
IDeal Installation Manual
(P/N 4022900)
Milk flowing but no weight
shown or only partial
weight shown
Electrodes dirty or coated
in milk lime
Perform acid wash with 1.5-2%
concentration
Defective AfiFree155
body or Terminal 155i
Milk flow stopped but
AfiFree155i continues to
measure and does not
remove the cluster
There are foreign particles
inside the body
Make sure there are no foreign
particles inside the body